DocumentCode :
2607097
Title :
The Effect of Wind on Corona Current Generated From DC Conductor in Corona Cage
Author :
Wang, Wei ; Yang, Bo ; Li, Chengrong ; Luo, Bing ; Li, Xiaolin ; Wang, Yixu ; An, Bing ; Fan, Fei
Author_Institution :
Beijing Key Lab. of High Voltage, North China Electr. Power Univ., Beijing, China
fYear :
2008
fDate :
9-12 Nov. 2008
Firstpage :
152
Lastpage :
153
Abstract :
To research the effect of wind on corona current generated from DC transmission lines, a mini corona cage and a wind generated system have been constructed. The corona current generated from a copper line in corona cage have been measured with wind and no wind. The relationship between corona current and voltage with wind and no wind have been observed and compared. There were about 3% ~ 7% increased for corona current generated from DC conductor caused by wind after corona onset.
Keywords :
DC generators; conductors (electric); corona; power transmission lines; wind power plants; DC conductor; DC transmission line; copper line; corona cage; corona current generation; wind effects; wind generated system; Conductors; Corona; Current measurement; DC generators; Power generation; Power transmission lines; Testing; Voltage; Wind energy generation; Wind power generation;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
High Voltage Engineering and Application, 2008. ICHVE 2008. International Conference on
Conference_Location :
Chongqing
Print_ISBN :
978-1-4244-3823-5
Electronic_ISBN :
978-1-4244-2810-6
Type :
conf
DOI :
10.1109/ICHVE.2008.4773896
Filename :
4773896
Link To Document :
بازگشت