DocumentCode
2607985
Title
A New Electrostatic Discharge Failure Mode
Author
Woods, M.H. ; Gear, G.
Author_Institution
Intel Corporation, Santa Clara, California 95051. (408) 987-8080
fYear
1978
fDate
28581
Firstpage
146
Lastpage
150
Abstract
A new electrostatic discharge failure mode was discovered which affects MOS LSI components in hermetic packages with nonconductive lids. Failure can be induced by spraying package lids with canned coolant. It is believed that charge from the freeze spray causes breakdown in the air-gap between the die surface and the lid. As a result, localized surface charging and field inversion occurs in the array, which produces leakage currents and circuit failure. The failure mode can be characterized by its recovery with either a strong UV exposure to the die surface or a DI water rinse.
Keywords
Air gaps; Coolants; Electric breakdown; Electrostatic discharge; Large scale integration; Leakage current; Packaging; Spraying; Surface charging; Surface discharges;