Abstract
The wide use of plastic encapsulated MOS-LSI integrated circuits (IC) has aroused much concern regarding moisture integrity testing. This paper discusses the results of both unbiased autoclave testing and 85°C/85% R.H. testing. Comparisons are made based on failure rate data, and a heuristic acceleration factor is determined.
Keywords
Acceleration; Circuit testing; Failure analysis; Integrated circuit testing; Life estimation; Life testing; Logic testing; Moisture; Plastic packaging; Stress;