• DocumentCode
    2609704
  • Title

    Research of Infrared Diagnosed of Faults of Arrester

  • Author

    Xingang, Chen ; Xiaoxiao, Tian ; Fan Li

  • Author_Institution
    Chongqing Inst. of Technol., Chongqing
  • fYear
    2008
  • fDate
    9-12 Nov. 2008
  • Firstpage
    637
  • Lastpage
    640
  • Abstract
    In order to analyze heat-characteristic in various fault of arrester, author using representational 6~10 kV and upward voltage grade of FZ, FCZ, MOA arrester and 110 kV arrester of four burl combination type which running in electric power system and wash out by preventive test, according to practicality running mode and equip homonymic eligibility element, arrester had been done broken-down simulate experimentation of bowel parallel resistance aging, humidify, parallel resistance rupture by 1.05~1.10 times rating voltage. At the same time contrast is testing result between infrared testing and general testing of DC leakage current, distributed voltage, and AC leakage current. Through the research of simulate experimentation for different fault of arrester, analyzed the heat-characteristic in different fault of arrester, then research and obtain the character of heat-image which in have and not fault of arrester, obtain some basic method to diagnosis and distinguish the fault of arrester. The result shows that heat of arrester mostly come of equal voltage badness of gaps of parallel resistance, and a number of heat-characteristic of vary arresters had been analyzed in order state and fault state, and gain some law of character of heat-image of arrester through simulate test and practice of locale detection.
  • Keywords
    arresters; failure analysis; fault diagnosis; infrared imaging; leakage currents; life testing; lightning protection; overvoltage protection; power system faults; power system measurement; AC leakage current testing; DC leakage current testing; FCZ arrester; FZ arrester; MOA arrester; arrester faults; arrester heat characteristics; bowel parallel resistance aging experiment; distributed voltage testing; electric power system; heat image; infrared fault diagnosis; infrared testing; voltage 110 kV; voltage 6 kV to 10 kV; Aging; Analytical models; Arresters; Cogeneration; Electric resistance; Leakage current; Power system simulation; Resistance heating; System testing; Voltage; Arrester; Character of heat-image; Fault; Infrared-diagnosed; Simulate-experimentation;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    High Voltage Engineering and Application, 2008. ICHVE 2008. International Conference on
  • Conference_Location
    Chongqing
  • Print_ISBN
    978-1-4244-3823-5
  • Electronic_ISBN
    978-1-4244-2810-6
  • Type

    conf

  • DOI
    10.1109/ICHVE.2008.4774016
  • Filename
    4774016