DocumentCode
2610468
Title
The Reflow Attachment and Reliability Testing of Ceramic Chip Carriers
Author
Charles, Harry K., Jr. ; Romenesko, Bruce M.
Author_Institution
The Johns Hopkins University, Applied Physics Laboratory, Johns Hopkins Road, Laurel, Maryland 20810
fYear
1981
fDate
29677
Firstpage
93
Lastpage
103
Abstract
The results of an extensive program for the solder reflow attachment and reliability testiny of ceramic chip carriers for use in space satellites, implantable biomedical electronics, and underwater instrumentation are discussed in detail. The program was divided in three major parts; 1) the packaging of integrated circuit chips in ceramic carriers; 2) the selection and qualification of solders, reflow methods and cleaning processes; and 3) the validation of the chip carrier-substrate system for high reliability applications. Military Standard environmental testing of ceramic chip carriers alone and carriers attached to thin film and thick film (multilayer) ceramic substrates, glass, sapphire, and various printed wire circuit boards has been conducted. Test results are presented for various carrier-substrate-solder combinations along with discussions of associated failure modes and fabrication problem areas.
Keywords
Application specific integrated circuits; Biomedical electronics; Ceramics; Circuit testing; Electronic equipment testing; Electronics packaging; Instruments; Integrated circuit packaging; Integrated circuit reliability; Satellites;
fLanguage
English
Publisher
ieee
Conference_Titel
Reliability Physics Symposium, 1981. 19th Annual
Conference_Location
Las Vegas, NV, USA
ISSN
0735-0791
Type
conf
DOI
10.1109/IRPS.1981.362980
Filename
4208379
Link To Document