• DocumentCode
    2611409
  • Title

    X-Ray Radiographic Techniques in Failure Analysis

  • Author

    Jones, Larry

  • Author_Institution
    Hewlett-Packard Company, 3404 E. Harmony Road, Fort Collins, Colorado 80525
  • fYear
    1982
  • fDate
    30011
  • Firstpage
    152
  • Lastpage
    155
  • Abstract
    High resolution techniques in X-ray analysis are presented. These techniques are non-destructive and use inexpensive film such as Polaroid Type 52 and Type 55, with short exposure time. Examples are given using various common electrical and mechanical components such as semiconductors, variable resistors, fuses, connectors with the aid of a microfiche viewer.
  • Keywords
    Aerospace materials; Circuit testing; Failure analysis; Fuses; Lead; Microscopy; Pins; Radiography; Semiconductor films; X-ray imaging;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Reliability Physics Symposium, 1982. 20th Annual
  • Conference_Location
    San Diego, NV, USa
  • ISSN
    0735-0791
  • Type

    conf

  • DOI
    10.1109/IRPS.1982.363036
  • Filename
    4208438