• DocumentCode
    2612432
  • Title

    Soft Pipes Cause Reliability Problem in Bipolar Integrated Circuits

  • Author

    Casey, Jack ; Lee, Jay ; Redman, D.John ; Zinmner, Don

  • Author_Institution
    Hewlett-Packard Corporation, Colorado Springs, CO 80907. (303) 598-1900
  • fYear
    1983
  • fDate
    30407
  • Firstpage
    191
  • Lastpage
    197
  • Abstract
    An investigation of yield-limiting bipolar emitter-collector shorts (commonly called "pipes") uncovered a "soft" pipe reliability problem. For us the major crystal defects causing pipes can be detected by Wright etching test wafers after epitaxial growth. The electrical effects of pipes become apparent during in-process probing and DC testing. Test patterns give a defect density figure which correlates with the corresponding etched wafer defect densities. Wafers which were below an appropriate defect level were shipped. Subsequent AC testing on a product line showed previously undetected, or "soft", pipes caused circuit timing errors and line returns from the customer. Both types of pipes were determined to be the result of secondary implantation of Carbon atoms arising from an ultrathin layer of vacuum pump oil. The Carbon atoms were knocked through the preimplant oxide during an Arsenic buried-layer implant step. Both types of pipes were eliminated by modifying the vacuum system on the implanter.
  • Keywords
    Atomic layer deposition; Bipolar integrated circuits; Circuit testing; Epitaxial growth; Etching; Implants; Integrated circuit reliability; Integrated circuit yield; Petroleum; Timing;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Reliability Physics Symposium, 1983. 21st Annual
  • Conference_Location
    Phoenix, AZ, USA
  • ISSN
    0735-0791
  • Type

    conf

  • DOI
    10.1109/IRPS.1983.361983
  • Filename
    4208504