Abstract :
Users must have data on maximum motor rotor surface temperatures under “normal operating conditions” to safely apply inverter-fed induction motors in hazardous Class I, Division 2 areas. Rotor surface temperature data is presented for a TEFC (totally enclosed fan cooled) chemical duty induction motor under various inverter setups and operating conditions. A proposed definition of “normal operating conditions” for inverter-fed induction motors is suggested for industry consideration
Keywords :
cooling; induction motors; invertors; rotors; safety; TEFC chemical duty induction motor; TEFC inverter-fed motors; hazardous Class I Division 2 areas; inverter-fed induction motors; maximum motor rotor surface temperatures; maximum rotor temperatures evaluation; normal operating conditions; operating conditions; totally enclosed fan cooled motors; Automation; Flammability; IEEE members; Ignition; Induction motors; Manufacturing industries; Rotors; Temperature; USA Councils; Variable speed drives;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Petroleum and Chemical Industry Conference, 2000. Record of Conference Papers. Industry Applications Society 47th Annual
Conference_Location :
San Antonio, TX
ISSN :
0090-3507
Print_ISBN :
0-7803-6334-5
Type :
conf
DOI :
10.1109/PCICON.2000.882779
Filename :
882779
Link To Document :
بازگشت