DocumentCode :
2614222
Title :
Analysis and evaluation of control techniques for active power filters: sliding mode control and proportional-integral control
Author :
Cardenas, V.M. ; Nunez, Ciro ; Vázquez, N.
Author_Institution :
Dept. de Electron., CENIDET, Cuernavaca, Mexico
Volume :
1
fYear :
1999
fDate :
14-18 Mar 1999
Firstpage :
649
Abstract :
This paper presents a three-phase shunt active power filter controlled by three different control strategies using a digital signal processor (DSP). The control techniques analyzed and compared are: sliding mode control (SMC), proportional-integral control (PI), and sliding mode control with proportional-integral controller (SMC-PI). Analysis and modeling of the shunt active power filter as well as simulation and experimental results are presented. The results show that the SMC controller has a better performance than PI and SMC-PI, allowing a low THD in the AC mains current and a fast transient response
Keywords :
active filters; digital signal processing chips; harmonic distortion; power harmonic filters; power system control; power system harmonics; transient response; two-term control; variable structure systems; AC mains current; DSP; active power filters; control strategies; control techniques; digital signal processor; fast transient response; low THD; proportional-integral control; proportional-integral controller; sliding mode control; three-phase shunt active power filter; Active filters; Control systems; Costs; Digital signal processing; Digital signal processors; Electronic mail; Pi control; Power harmonic filters; Proportional control; Sliding mode control;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Applied Power Electronics Conference and Exposition, 1999. APEC '99. Fourteenth Annual
Conference_Location :
Dallas, TX
Print_ISBN :
0-7803-5160-6
Type :
conf
DOI :
10.1109/APEC.1999.749763
Filename :
749763
Link To Document :