DocumentCode
2614494
Title
A Novel Method for Measuring Nonuniformities in Metallization Temperatures of an Operating Integrated Circuit
Author
Clinton, Robert R.
Author_Institution
Florida Institute of Technology, Department of Physics and Space Science, Melbourne, Florida 32901. (305) 768-8098
fYear
1986
fDate
31503
Firstpage
19
Lastpage
23
Abstract
A nonuniform temperature distribution was observed along the metallization and on the top surface of an integrated circuit. Very small latex SEM calibration spheres were distributed over the circuit, and their changes of shape and contrast, due to melting, allowed us to discern hotter and cooler regions on the chip. Much of what was observed seemed to indicate that electromigration can take place at a relatively low temperature, around 113°C or less. Further discussion of the thermal calibration of the spheres, effects of the surface, and the effects of the vacuum is also given. Various difficulties involved with the technique and some proposals to overcome them are given as well.
Keywords
Calibration; Circuit testing; Electromigration; Heat transfer; Integrated circuit measurements; Integrated circuit metallization; Scanning electron microscopy; Shape; Space technology; Temperature distribution;