• DocumentCode
    2614494
  • Title

    A Novel Method for Measuring Nonuniformities in Metallization Temperatures of an Operating Integrated Circuit

  • Author

    Clinton, Robert R.

  • Author_Institution
    Florida Institute of Technology, Department of Physics and Space Science, Melbourne, Florida 32901. (305) 768-8098
  • fYear
    1986
  • fDate
    31503
  • Firstpage
    19
  • Lastpage
    23
  • Abstract
    A nonuniform temperature distribution was observed along the metallization and on the top surface of an integrated circuit. Very small latex SEM calibration spheres were distributed over the circuit, and their changes of shape and contrast, due to melting, allowed us to discern hotter and cooler regions on the chip. Much of what was observed seemed to indicate that electromigration can take place at a relatively low temperature, around 113°C or less. Further discussion of the thermal calibration of the spheres, effects of the surface, and the effects of the vacuum is also given. Various difficulties involved with the technique and some proposals to overcome them are given as well.
  • Keywords
    Calibration; Circuit testing; Electromigration; Heat transfer; Integrated circuit measurements; Integrated circuit metallization; Scanning electron microscopy; Shape; Space technology; Temperature distribution;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Reliability Physics Symposium, 1986. 24th Annual
  • Conference_Location
    Anaheim, CA, USA
  • ISSN
    0735-0791
  • Type

    conf

  • DOI
    10.1109/IRPS.1986.362106
  • Filename
    4208636