• DocumentCode
    2614557
  • Title

    Comprehensive Model for Humidity Testing Correlation

  • Author

    Peck, D.Stewart

  • Author_Institution
    3646 Highland St., Allentown, PA 18104. (215) 398-1222
  • fYear
    1986
  • fDate
    31503
  • Firstpage
    44
  • Lastpage
    50
  • Abstract
    This paper reviews all published life in humidity conditions vs life at 85C/85% RH for epoxy packages; 61 data points are used. An acceleration formula is described which provides direct extrapolation from test results in autoclave tests at up to at least 140C to low-humidity down to below 30XRH. This formula compares favorably with previously-published formulae. The possible effect of the Tg of the epoxy is recognized, and other high-temperature and low-humidity effects are disclosed. Recommendat ions are made for future tests, replacing 1000 hours at 85C/85%RH with a 20-hour test at 140C/100%RH, to reduce test time and increase test usefulness.
  • Keywords
    Extrapolation; Failure analysis; Humidity; Life estimation; Materials testing; Measurement standards; Packaging; Particle measurements; Stress measurement; Temperature;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Reliability Physics Symposium, 1986. 24th Annual
  • Conference_Location
    Anaheim, CA, USA
  • ISSN
    0735-0791
  • Type

    conf

  • DOI
    10.1109/IRPS.1986.362110
  • Filename
    4208640