• DocumentCode
    2614611
  • Title

    Moisture Determination in IC Packages by Conductance Technique

  • Author

    Annamalai, N.K. ; Islam, S.M.R.

  • Author_Institution
    Rome Air Development Center, Solid State Sciences Division, Hanscom AFB, MA 01731
  • fYear
    1986
  • fDate
    31503
  • Firstpage
    61
  • Lastpage
    68
  • Abstract
    An a.c. conductance technique using a lock-in-amplifier (LIA) is described. The conductance technique is a non-destructive technique and uses the die as a sensor. Our experiments and theoretical calculations revealed that the moisture-induced conductance variation is 10 to 400% whereas the moisture-induced capacitance variation is 0 to 20%. Hence, even though capacitance and conductance values were measured, only conductance variations are reported. A circuit model has been developed to explain the observed experimental behavior. This technique is thus superior to capacitance technique in deterining the low levels of moisture (<5000ppmu) in IC packages. The selective condensation problem experienced in the Harris or Al2O3 sensors is non existent in the conductance technique. Since the applied voltage in the conductance method is ~l00mV, there is no dissociation of water into hydrogen and oxygen, as is possible in the case of Harris sensors. Further, the moisture content determined by this non-destructive technique correlates well with the residual gas analysis (RGA) by the mass spectrometer. This technique is non-destructive, reliable, rapid and suitable for in-line testing.
  • Keywords
    Calibration; Capacitance measurement; Diodes; Frequency; Integrated circuit packaging; Moisture; Pins; Semiconductor device measurement; Temperature sensors; Voltage;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Reliability Physics Symposium, 1986. 24th Annual
  • Conference_Location
    Anaheim, CA, USA
  • ISSN
    0735-0791
  • Type

    conf

  • DOI
    10.1109/IRPS.1986.362113
  • Filename
    4208644