• DocumentCode
    2617686
  • Title

    Design of a high resolution, monolithic crystal, PET/MRI detector with DOI positioning capability

  • Author

    Miyaoka, Robert S. ; Li, Xiaoli ; Lockhart, Cate ; Lewellen, Tom K.

  • Author_Institution
    University of Washington Department of Radiology, Seattle, USA
  • fYear
    2008
  • fDate
    19-25 Oct. 2008
  • Firstpage
    4688
  • Lastpage
    4692
  • Abstract
    We report on a high resolution, monolithic crystal PET detector design concept that provides depth of interaction (DOI) positioning within the crystal and is compatible for operation in a MRI scanner to support multimodal anatomic and functional imaging. Our design utilizes a novel sensor on the entrance surface (SES) approach combined with a maximum likelihood positioning algorithm. The sensor will be a two-dimensional array of micro-pixel avalanche photodiodes (MAPD). MAPDs are a new type of solid-state photodetector with Geiger mode operation that can provide signal gain similar to a photomltipiler tube (PMT). In addition, they can be operated in high magnetic fields to support PET/MR imaging. Utilizing a multi-step simulation process, we determined the intrinsic spatial resolution characteristics for a variety of detector configurations. The crystal was always modeled as a 48.8 mm by 48.8 mm by 15 mm monolithic slab of a lutetium-based scintillator. The SES design was evaluated via simulation for three different two-dimensional MAPD array sizes: 8×8 with 5.8×5.8 mm2 pads; 12×12 with 3.8×3.8mm2 pads; and 16×16 with 2.8×2.8 mm2 pads. To reduce the number of signal channels row-column summing readout was explored for the 12×12 and 16×16 channel array devices. The intrinsic spatial resolution for the 8x8 MAPD array is 0.88 mm FWHM in X and Y, and 1.83 mm FWHM in Z (i.e., DOI). Comparing the results versus using a conventional design with the photosensors on the backside of the crystal, an average improvement of ∼24% in X and Y and 20% in Z is achieved. The X, Y intrinsic spatial resolution improved to 0.66 mm and 0.65 mm FWHM for the 12×12 and 16×16 MAPDs using row-column readout. Using the 12×12 and 16×16 arrays also led to a slight improvement in the DOI positioning accuracy.
  • Keywords
    Algorithm design and analysis; Detectors; High-resolution imaging; Image resolution; Magnetic resonance imaging; Magnetic sensors; Maximum likelihood detection; Positron emission tomography; Sensor arrays; Spatial resolution;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Nuclear Science Symposium Conference Record, 2008. NSS '08. IEEE
  • Conference_Location
    Dresden, Germany
  • ISSN
    1095-7863
  • Print_ISBN
    978-1-4244-2714-7
  • Electronic_ISBN
    1095-7863
  • Type

    conf

  • DOI
    10.1109/NSSMIC.2008.4774469
  • Filename
    4774469