• DocumentCode
    2618065
  • Title

    An improvement on steam turbine generator trip caused by voltage sag

  • Author

    Ning, C.C. ; Tsao, T.P.

  • fYear
    2004
  • fDate
    10-13 Oct. 2004
  • Firstpage
    624
  • Abstract
    This paper attempts suggest improvements on Nan-Pu combined cycle power plant, which is located in Kaoshiung of Taiwan. As far as transient outage of power system in southern Taiwan is concerned, the steam turbine generator would trip but the gas turbine generator would keep running. The outages had occurred several times since commercial synchronization; it happened as many as three times from January to June in 2001. Consequently, we found that the settings of overcurrent protection relay of excitation transformer were improper in our investigation and through with the other plant. By modifying the relay settings, this defect has already been corrected fully. The project not only improve working achievement, but also enhance transient stability of overall power system in Taiwan.
  • Keywords
    boilers; combined cycle power stations; overcurrent protection; power supply quality; power system transient stability; power transformers; relay protection; steam turbines; Kaoshiung; Nan-Pu combined cycle power plant; Taiwan; gas turbine generator; overcurrent protection relay; power system transient stability; steam turbine generator; synchronization; transformer; voltage sag; Electric shock; Industrial power systems; Power generation; Power system protection; Power system relaying; Power system stability; Power system transients; Protective relaying; Turbines; Voltage fluctuations;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Power Systems Conference and Exposition, 2004. IEEE PES
  • Print_ISBN
    0-7803-8718-X
  • Type

    conf

  • DOI
    10.1109/PSCE.2004.1397712
  • Filename