Abstract
Results from the test of a full sector of the front-end electronics developed for the Resistive Plate Chamber of HADES are presented. This new detector for the Time-of-Flight detection system contains 1116 electrically shielded RPC cells read by 2232 electronic channels, covering a total active area of nearly 8 m2. The front-end electronics consist of custom-made boards that allow achieving a time resolution better than 100 ps to fulfill the new HADES requirements.
Keywords
Crosstalk; Detectors; Electronic equipment testing; Gas insulated transmission lines; Helium; Nuclear and plasma sciences; Nuclear electronics; Stability; System testing; Timing; Front-end electronics; RPC electronics; time-of-flight; timing with charge correction;