• DocumentCode
    2622556
  • Title

    An Accurate Millimeter Wave Loss and Delay Measurement Set

  • Author

    Chasek, M.B.

  • Volume
    62
  • Issue
    1
  • fYear
    1961
  • fDate
    15-17 May 1961
  • Firstpage
    89
  • Lastpage
    93
  • Abstract
    A point-by-point millimeter wave loss and delay measurement system has been built which combines large dynamic range with high accuracy. Up to 80 db loss and 100 nanoseconds envelope delay can be measured in the 50-60 Gc/s range. The accuracy for 0-40 db loss measurements is /spl plusmn/0.05 db, while beyond that accuracy is progressively diminished to /spl plusmn/0.8 db at 80 db. Delay accuracy for low loss devices (0-20 db) is /spl plusmn/0.2 /spl mu/sec over the entire 100 /spl mu/sec range. High accuracy and large range are attained with a substitution heterodyne measurement scheme using rapid RF and IF comparison switching along with calibrated IF loss and delay standards. In addition, high gain, narrow band, IF amplification and differential null detection is employed. Both measurement functions are incorporated into one system with manual waveguide switching and preset IF programs to facilitate conversion from loss to delay.
  • Keywords
    Detectors; Dynamic range; Loss measurement; Measurement standards; Microwave generation; Millimeter wave measurements; Narrowband; Propagation delay; Signal generators; Switching circuits;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    PGMTT National Symposium Digest
  • Conference_Location
    Washington, DC, USA
  • Type

    conf

  • DOI
    10.1109/PGMTT.1962.1122393
  • Filename
    1122393