DocumentCode :
2622705
Title :
Aging effects and operational experience with the CDF run II silicon detector
Author :
Husemann, U.
Author_Institution :
Deutsches Elektronen-Synchrotron DESY, Platanenallee 6, D-15738 Zeuthen, Germany
fYear :
2008
fDate :
19-25 Oct. 2008
Firstpage :
1904
Lastpage :
1908
Abstract :
The silicon detector system of the CDF-II experiment at the Tevatron proton-antiproton collider at Fermi National Accelerator Laboratory has been operated successfully since the start of Tevatron Run II in 2001. In this article we summarize the experience gained with the silicon detector system, focusing on automation and aging effects of detector components during the years 2006–2008. In addition, we present the most recent updates on studies of single event upsets and radiation damage to the silicon sensors.
Keywords :
Aging; Collaboration; Detectors; Instruments; Laboratories; Monitoring; Particle tracking; Physics; Proton accelerators; Silicon; High-energy physics instrumentation; radiation damage; silicon strip detectors;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Nuclear Science Symposium Conference Record, 2008. NSS '08. IEEE
Conference_Location :
Dresden, Germany
ISSN :
1095-7863
Print_ISBN :
978-1-4244-2714-7
Electronic_ISBN :
1095-7863
Type :
conf
DOI :
10.1109/NSSMIC.2008.4774761
Filename :
4774761
Link To Document :
بازگشت