Title :
Calibration of a highly granular hadronic calorimeter with SiPM readout
Author_Institution :
Max-Planck-Institut fÿr Physik, Munich, Germany
Abstract :
A highly granular hadronic calorimeter (HCAL) based on scintillator tiles with individual readout by silicon photomultipliers (SiPMs) has been constructed by the CALICE collaboration and has been tested extensively in particle beams at CERN. The 7608 SiPMs coupled to scintillator tiles in the approximately 1 cubic meter large calorimeter allow large sample studies of behavior of these devices under varying voltage and temperature as well as their saturation behavior. We also present detailed studies of the temperature dependence of the calorimeter signal in muon and hadron beams. The calibration of the full calorimeter using muons is discussed. In addition, a novel method for calibration and detector studies using minimum-ionizing track segments in hadronic showers, is explored.
Keywords :
Calibration; Collaboration; Mesons; Particle beams; Photomultipliers; Silicon; Temperature; Testing; Tiles; Voltage; CALICE; Hadronic Calorimetry; ILC; Silicon Photomultiplier;
Conference_Titel :
Nuclear Science Symposium Conference Record, 2008. NSS '08. IEEE
Conference_Location :
Dresden, Germany
Print_ISBN :
978-1-4244-2714-7
Electronic_ISBN :
1095-7863
DOI :
10.1109/NSSMIC.2008.4774798