DocumentCode
2623404
Title
Drift-time calibration of the ATLAS Monitored Drift Tubes with a precision mini-chamber
Author
Levin, Daniel S. ; Amram, Nir ; ben Moshe, Meni ; Etzion, Erez ; Dai, Tiesheng ; Diehl, Edward B. ; Ferretti, Claudio ; Gregory, Jeffery ; Kiesel, Mike ; Thun, Rudi ; Weaverdyck, Curtis ; Wilson, Alan ; Zhou, Bing
Author_Institution
Department of Physics, University of Michigan, USA
fYear
2008
fDate
19-25 Oct. 2008
Firstpage
2266
Lastpage
2269
Abstract
Muon track reconstruction in the ATLAS Muon Precision (MDT) Chambers relies on many thousands of calibration parameters: T-zeros offsets and on time-to-space (RT) functions that convert drift time to drift radius. A data intensive computing program has been created to obtain compute these constants daily for each of thousands of muon-spectrometer subregions. For early LHC running a simplified calibration employing a single universal RT function (URT) provided by a dedicated gas-monitor MDT chamber can be invoked. Constructed with standard MDT’s, the monitor chamber records cosmic ray drift-time spectra derived from gas flowing in the input and output arteries of the main ATLAS MDT gas supply. These spectra are used to compute the URT bi-hourly, referenced to a standard operating pressure and temperature.
Keywords
Assembly; Calibration; Large Hadron Collider; Magnetic multilayers; Mesons; Monitoring; Spatial resolution; Spectroscopy; Temperature measurement; Toroidal magnetic fields;
fLanguage
English
Publisher
ieee
Conference_Titel
Nuclear Science Symposium Conference Record, 2008. NSS '08. IEEE
Conference_Location
Dresden, Germany
ISSN
1095-7863
Print_ISBN
978-1-4244-2714-7
Electronic_ISBN
1095-7863
Type
conf
DOI
10.1109/NSSMIC.2008.4774805
Filename
4774805
Link To Document