DocumentCode :
2623466
Title :
Comparison of SE measurements between MIL-STD-285 and the ASTM Standard E1851
Author :
Lee, Youn M.
Author_Institution :
US Army Res. Lab., Adelphi, MD, USA
Volume :
2
fYear :
1998
fDate :
24-28 Aug 1998
Firstpage :
1053
Abstract :
The American Society for Testing and Materials (ASTM) published a standard test method (E1851) for electromagnetic shielding effectiveness (SE) of a room-size transportable shielded enclosure. A baseline set of data has been collected to compare both SE measurement results and the length of testing time for the modified MIL-STD-285 and the ASTM Standard E1851
Keywords :
electromagnetic shielding; standards; ASTM Standard E1851; American Society for Testing and Materials; MIL-STD-285; electromagnetic shielding effectiveness measurements; room-size transportable shielded enclosure; testing time length; Frequency; Magnetic field measurement; Magnetic materials; Magnetic shielding; Materials testing; Measurement standards; Qualifications; Standards development; Standards publication; Time measurement;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electromagnetic Compatibility, 1998. 1998 IEEE International Symposium on
Conference_Location :
Denver, CO
Print_ISBN :
0-7803-5015-4
Type :
conf
DOI :
10.1109/ISEMC.1998.750354
Filename :
750354
Link To Document :
بازگشت