• DocumentCode
    2623500
  • Title

    ATLAS monitored drift tube chambers in E = 11 MeV neutron background

  • Author

    Müller, T. ; Mlynek, A. ; Biebel, O. ; Hertenberger, R. ; Nunnemann, T. ; Merkl, D. ; Rauscher, F. ; Schaile, D. ; Ströhmer, R.

  • fYear
    2008
  • fDate
    19-25 Oct. 2008
  • Firstpage
    2284
  • Lastpage
    2287
  • Abstract
    The influence of fast neutrons on the occupancy and the single tube resolution of ATLAS muon drift detectors was investigated by exposing a chamber built out of 3 layers of 3 short standard drift tubes to neutron flux-densities of up to 16 kHz/cm2 at a neutron energy of E=11 MeV. Pulse shape capable NE213 scintillaton detectors and a calibrated BF3 neutron detector provided monitoring of the neutron flux-density and energy. The sensitivity of the drift chamber to the neutrons was measured to be 4*10−4 by comparing data sets with and without neutron background. For the investigation of tracks of cosmic muons two silicon-strip detectors above and underneath the chamber allow to compare measured drift-radii with reference tracks. Alternatively, the single tube resolution was determined using the triple-sum method. The comparison between data with and without neutron irradiation shows only a marginal effect on the resolution and little influence on the muon track reconstruction.
  • Keywords
    Detectors; Electron tubes; Energy resolution; Hydrogen; Mesons; Monitoring; Neutrons; Nuclear and plasma sciences; Pulse shaping methods; Spectroscopy;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Nuclear Science Symposium Conference Record, 2008. NSS '08. IEEE
  • Conference_Location
    Dresden, Germany
  • ISSN
    1095-7863
  • Print_ISBN
    978-1-4244-2714-7
  • Electronic_ISBN
    1095-7863
  • Type

    conf

  • DOI
    10.1109/NSSMIC.2008.4774811
  • Filename
    4774811