• DocumentCode
    2624272
  • Title

    Use of standard CMOS pixel imagers as ionizing radiation detectors

  • Author

    Servoli, L. ; Biagetti, D. ; Passeri, D. ; Gattuso, E.Spanti

  • Author_Institution
    Istituto Nazionale di Fisica Nucleare, Sezione di Perugia, I-06132 Italy
  • fYear
    2008
  • fDate
    19-25 Oct. 2008
  • Firstpage
    2484
  • Lastpage
    2488
  • Abstract
    The recent developments in the domain of the standard CMOS imagers for visible light, mainly in the reduction of the pixel size, has led us to investigate the suitability of some of these devices as ionizing radiation detectors. A standard 640x480 imager with 5.6x5.6 micrometer pixel size (Micron product type MT9V011) has been characterized with both photons ( 55Fe and 8 keV X-ray tube) than charged particles sources ( 500 MeV electrons). The main results obtained are: a small pixel multiplicity (4–5), for the detection of either X-ray or charged particles; a good linearity of the response; a S/N ratio ≫ 30 for a Minimum Ionizing Particle and an estimated sensitivity down to about 2 keV.
  • Keywords
    Electron tubes; Ionizing radiation; Iron; Linearity; Pixel; Radiation detectors; Standards development; X-ray detection; X-ray detectors; X-ray imaging;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Nuclear Science Symposium Conference Record, 2008. NSS '08. IEEE
  • Conference_Location
    Dresden, Germany
  • ISSN
    1095-7863
  • Print_ISBN
    978-1-4244-2714-7
  • Electronic_ISBN
    1095-7863
  • Type

    conf

  • DOI
    10.1109/NSSMIC.2008.4774860
  • Filename
    4774860