• DocumentCode
    2624539
  • Title

    Techniques for Providing TWM´s with Wide Instantaneous Bandwidths

  • Author

    DeGruyl, J.A. ; Okwit, S. ; Smith, J.G.

  • Volume
    65
  • Issue
    1
  • fYear
    1965
  • fDate
    5-7 May 1965
  • Firstpage
    193
  • Lastpage
    198
  • Abstract
    The paramagnetic material in a conventional TWM is uniformly distributed in a slow-wave structure located in a homogeneous DC magnetic field. The spin distribution-function has a Lorentzian shape which constitutes a fixed relationship between Gain (db) and 3 db bandwidth, namely, B/sub 3/ = B/sub m/ /spl radic/ 3/G/sub db/-3/. Applying an inhomogeneous DC magnetic field, we can overcome this limitation and make gain and bandwidth both independent variables.
  • Keywords
    Automotive materials; Bandwidth; Instruments; Laboratories; Magnetic fields; Magnetic materials; Magnetic separation; Paramagnetic materials; Scanning probe microscopy;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    G-MTT Symposium Digest, 1965
  • Conference_Location
    Clearwater, Florida, USA
  • Type

    conf

  • DOI
    10.1109/GMTT.1965.1122504
  • Filename
    1122504