• DocumentCode
    2625732
  • Title

    Needle Insertion Point and Orientation Optimization in Non-linear Tissue with Application to Brachytherapy

  • Author

    Dehghan, Ehsan ; Salcudean, Septimiu E.

  • Author_Institution
    Dept. of Electr. & Comput. Eng., British Columbia Univ., Vancouver, BC
  • fYear
    2007
  • fDate
    10-14 April 2007
  • Firstpage
    2267
  • Lastpage
    2272
  • Abstract
    This paper presents a new method of optimizing the needle insertion point, heading and depth for needle insertion into deformable tissue. The goal is to minimize the distance between a number of specified targets and the needle. Assuming a rigid needle and a deformable tissue described by a finite element model, an iterative optimization method is proposed that uses the needle insertion simulation. At each iteration, the best fitted 3D line to the targets in the simulated deformed configuration is used as a candidate for the new insertion line in the next iteration. This method has been implemented in a prostate brachytherapy simulator to minimize seed misplacement errors. The targets are designed to lie on a straight line in the undeformed configuration inside the prostate. To increase the accuracy while simulating the prostate rotation, a non-linear model is used. The neo-Hookean material model is exploited to determine the effects of geometric and mechanical nonlinearities and compressibility effects. It is shown that the optimization algorithm converges in few iterations and decreases the targeting error effectively.
  • Keywords
    biological organs; biological tissues; brachytherapy; control nonlinearities; finite element analysis; iterative methods; medical control systems; needles; optimisation; position control; deformable tissue; finite element model; geometric nonlinearities; iterative optimization method; mechanical nonlinearities; needle insertion point; needle orientation optimization; neoHookean material model; nonlinear model; nonlinear tissue; prostate brachytherapy; prostate rotation; seed misplacement error; Brachytherapy; Deformable models; Finite element methods; Iterative methods; Needles; Optimization methods; Prostate cancer; Robotics and automation; Robots; Solid modeling;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Robotics and Automation, 2007 IEEE International Conference on
  • Conference_Location
    Roma
  • ISSN
    1050-4729
  • Print_ISBN
    1-4244-0601-3
  • Electronic_ISBN
    1050-4729
  • Type

    conf

  • DOI
    10.1109/ROBOT.2007.363657
  • Filename
    4209421