Title :
Lightning unit control & design for high speed acquisition and light microscopy
Author :
Koniar, Dusan ; Hargas, Libor ; Stofan, Stanisiav ; Paskala, Marek
Author_Institution :
Dept. of Mechatron. & Electron., Univ. of Zilina, Zilina, Slovakia
Abstract :
The accuracy of cinematic analysis with camera system depends on frame rate of used camera. Specific case of cinematic analysis is in medical research focusing on microscopic objects moving with high frequencies (cilia of respiratory epithelium). Higher frame rate of camera (400 fps e.g.) causes that exposure time for imaging sensor is too short, so it is necessary to use lightning source with higher optical (illuminating) efficiency and higher reliability. Paper focuses on design of LED illumination modules, their control and supplying circuits for high speed imaging purposes.
Keywords :
biomedical equipment; cameras; cinematography; image sensors; light emitting diodes; optical microscopy; reliability; LED illumination modules; camera system; cinematic analysis; high speed acquisition; high speed imaging; imaging sensor; light microscopy; lightning source; lightning unit control; lightning unit design; medical research; microscopic objects; reliability; Biological information theory; Lighting; Microscopy; Moment methods; LED modules; Light microscopy; high speed imaging; illumination control; illumination parameters;
Conference_Titel :
IECON 2012 - 38th Annual Conference on IEEE Industrial Electronics Society
Conference_Location :
Montreal, QC
Print_ISBN :
978-1-4673-2419-9
Electronic_ISBN :
1553-572X
DOI :
10.1109/IECON.2012.6388511