Title :
Sensitivity of gamma-ray source detection using 3D-position-sensitive semiconductor detectors
Author :
Wahl, Christopher G. ; He, Zhong
Author_Institution :
Department of Nuclear Engineering and Radiological Sciences, University of Michigan, Ann Arbor, 48109 USA
Abstract :
Three-dimensional-position-sensitive semiconductor detectors provide both the energy and the locations of each gamma-ray interaction. From these data, Compton-imaging methods can reconstruct the source distribution around the detector as a function of energy. Known isotopes are detected using the generalized likelihood ratio test (GLRT), and the performance is presented as a function of false-alarm probability for the cases of known and unknown background intensity. In addition, the localization performance is presented using two different algorithms as a function of measurement time for a point source in background using experimental data from a 20 mm × 20 mm × 15 mm CdZnTe detector. The effect of energy resolution on detection performance is also noted. Imaging information is hence used along with spectroscopic information to improve the search for a hidden source.
Keywords :
Energy resolution; Gamma ray detection; Gamma ray detectors; Helium; High-resolution imaging; Image reconstruction; Optical imaging; Position measurement; Radiation detectors; Testing;
Conference_Titel :
Nuclear Science Symposium Conference Record, 2008. NSS '08. IEEE
Conference_Location :
Dresden, Germany
Print_ISBN :
978-1-4244-2714-7
Electronic_ISBN :
1095-7863
DOI :
10.1109/NSSMIC.2008.4775058