DocumentCode :
2628949
Title :
Inductive power transmission system with stabilized output voltage using local primary-and secondary-side control
Author :
Wambsganss, Peter ; Huwig, Dominik
Author_Institution :
Corp. Res., RRC power solutions GmbH, Homburg, Germany
fYear :
2010
fDate :
6-8 Sept. 2010
Abstract :
In this paper, a primary and secondary series compensated inductive power transmission system with primary-side zero phase angle control and a loss-free clamp (LFC) circuit on the secondary-side is described. The effects of non-synchronous tuning are analyzed and intendet detuning is proposed to guarantee controllability. The functional principle of the LFC circuit, which is required for output voltage stabilization over a wide load range and varying magnetic coupling, is explained. Finally, theoretical results are verified experimentally.
Keywords :
power transmission; stability; inductive power transmission system; intendet detuning; loss-free clamp circuit; magnetic coupling; nonsynchronous tuning; output voltage stabilization; primary-side zero phase angle control; secondary-side control; Couplings; Inductive power transmission; RLC circuits; Resistance; Resonant frequency; Tuning; Voltage control; Wireless power transmission; efficiency; output voltage stabilization;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Power Electronics and Motion Control Conference (EPE/PEMC), 2010 14th International
Conference_Location :
Ohrid
Print_ISBN :
978-1-4244-7856-9
Type :
conf
DOI :
10.1109/EPEPEMC.2010.5606616
Filename :
5606616
Link To Document :
بازگشت