• DocumentCode
    2629726
  • Title

    Millimeter Wave Imaging

  • Author

    Feingold, B.R. ; Levin, B.J.

  • fYear
    1970
  • fDate
    11-14 May 1970
  • Firstpage
    126
  • Lastpage
    130
  • Abstract
    A millimeter wave imaging system using a semiconductor panel as an image dissector has been evaluated at 80 GHz and 140 GHz using both optomechanical and electron beam scanning methods. Images of groups of simple reflecting targets were found easily resolvable at separations approaching the theoretical minimum.
  • Keywords
    Absorption; Conductivity; Electron beams; Image resolution; Laboratories; Lenses; Microwave imaging; Millimeter wave technology; Optical imaging; Optical reflection;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Microwave Symposium, G-MTT 1970 International
  • Conference_Location
    Newport Beach, CA, USA
  • Type

    conf

  • DOI
    10.1109/GMTT.1970.1122786
  • Filename
    1122786