• DocumentCode
    2629773
  • Title

    Rational sizing of onboard EDLC and placement of charging facilities for a LRT system with intermittent power supply

  • Author

    Endo, Naoto ; Miyatake, Masafumi

  • Author_Institution
    Grad. Sch. of Electr. & Electron. Eng., Sophia Univ., Tokyo, Japan
  • fYear
    2015
  • fDate
    3-5 March 2015
  • Firstpage
    1
  • Lastpage
    6
  • Abstract
    The optimal operation of catenary free Light Rail Transit (LRT) with onboard energy storage device minimizing energy consumption is discussed in this paper. The Electric Double Layer Capacitor (EDLC) is assumed as an energy storage device because of its high power density, long lifetime and quick charge/discharge. The proposed method can determine the optimal capacitance of the EDLC and placement of charging facility at different cases for the purpose of saving the energy consumption. The trend of the optimal design of the EDLC sizing and the charging facility placement is finally discussed qualitatively.
  • Keywords
    battery storage plants; energy consumption; light rail systems; supercapacitors; EDLC; LRT; catenary free light rail transit; charging facility placement; electric double layer capacitor; energy consumption; onboard energy storage device; optimal capacitance; Capacitance; Capacitors; Energy consumption; Energy storage; Power supplies; Rail transportation; Resistance; Electric railway; capacitor; catenary-free; contactless power transfer; energy-saving; light rail transit;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electrical Systems for Aircraft, Railway, Ship Propulsion and Road Vehicles (ESARS), 2015 International Conference on
  • Conference_Location
    Aachen
  • Type

    conf

  • DOI
    10.1109/ESARS.2015.7101521
  • Filename
    7101521