Abstract :
The efficiency and life expectancy of PV grid-tie micro-inverter is of critical effect to its performance. The Actively Clamped Resonant DC-link Inverter has remarkable features of simple structure and high efficiency with only one auxiliary switch. The short-circuit control is the traditional clamp circuit control strategy. But the short-circuit process increases the DC-link losses and the control complexity. A no short-circuit control strategy is presented to overcome the above problems. The calculation results show that no short-circuit control strategy reduces the loss of inverter. Film capacitor is chosen to be the clamp capacitor.
Keywords :
capacitors; clamps; invertors; short-circuit currents; voltage control; PV grid-tie microinverter; actively clamped resonant DC-link inverter; clamp capacitor; clamp circuit control; clamping voltage control; control complexity; film capacitor; short-circuit control; Actively clamped resonant dc-link inverter; Loss calculation; Micro-inverter; No short-circuit control strategy; Two-amplitude control;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
IECON 2012 - 38th Annual Conference on IEEE Industrial Electronics Society
Conference_Location :
Montreal, QC
ISSN :
1553-572X
Print_ISBN :
978-1-4673-2419-9
Electronic_ISBN :
1553-572X
Type :
conf
DOI :
10.1109/IECON.2012.6388632
Filename :
6388632
Link To Document :
بازگشت