• DocumentCode
    2630226
  • Title

    Automatic 2D segmentation of the left ventricle in tagged cardiac MRI using motion information

  • Author

    Milles, Julien ; Van Susteren, Anneke ; Arts, Theo ; Clarysse, Patrick ; Croisille, Pierre ; Magnin, Isabelle E.

  • Author_Institution
    Maastricht Univ., Netherlands
  • fYear
    2004
  • fDate
    15-18 April 2004
  • Firstpage
    153
  • Abstract
    A new algorithm is presented to automatically segment the left ventricle from tagged MR images using motion information. This segmentation method is based on a deformable template which is fitted to tags´ envelope image through an iterative process. Motion information is used for initializing the template. The method has been evaluated both on simulated and 5 in vivo datasets. A 5 slice levels, 36 frames per slice dataset is fully segmented in less than 10 minutes. The method proposed here has the potential to overcome the main drawbacks of previous approaches, such as user supervision and computing time, to foresee routine clinical use of tagged cardiac MRI.
  • Keywords
    biomedical MRI; cardiology; image motion analysis; image segmentation; medical image processing; automatic 2D segmentation; deformable template; iterative process; left ventricle; motion information; tagged cardiac MRI; Art; Deformable models; Image segmentation; Iterative algorithms; Magnetic resonance imaging; Milling machines; Motion estimation; Myocardium; Solid modeling; Strain measurement;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Biomedical Imaging: Nano to Macro, 2004. IEEE International Symposium on
  • Print_ISBN
    0-7803-8388-5
  • Type

    conf

  • DOI
    10.1109/ISBI.2004.1398497
  • Filename
    1398497