DocumentCode :
2631265
Title :
Compensation of transient error in sensorless alternating carrier injection scheme
Author :
Ghazimoghadam, M.A. ; Tahami, F.
Author_Institution :
Dept. of Electr. Eng., Sharif Univ. of Technol., Tehran, Iran
fYear :
2012
fDate :
25-28 Oct. 2012
Firstpage :
1702
Lastpage :
1706
Abstract :
High frequency (HF) carrier injection schemes can estimate rotor position in a wide speed range. In these methods, first a HF voltage is injected to stator windings and then the corresponding HF current is exploited to estimate the position of rotor using a closed loop tracking observer. The tracking observer is capable to track rotor saliency with no steady state error. However when the motor starts to move or whenever the rotor speed changes a transient error appears. In this paper a new solution is proposed to compensate the transient error in estimation of rotor position.
Keywords :
closed loop systems; observers; permanent magnet motors; sensorless machine control; synchronous motors; HF voltage; closed loop tracking observer; high frequency carrier injection schemes; permanent magnet synchronous motors; rotor position; rotor saliency tracking; sensorless alternating carrier injection scheme; stator windings; steady state error; transient error compensation; Estimation; Zirconium; Carrier injection method; permanent magnet synchronous machine; sensorless position control; stator inductance estimation;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
IECON 2012 - 38th Annual Conference on IEEE Industrial Electronics Society
Conference_Location :
Montreal, QC
ISSN :
1553-572X
Print_ISBN :
978-1-4673-2419-9
Electronic_ISBN :
1553-572X
Type :
conf
DOI :
10.1109/IECON.2012.6388718
Filename :
6388718
Link To Document :
بازگشت