DocumentCode
2631988
Title
Open-Circuit fault detection analysis for indirect matrix converter in Microturbine generation systems
Author
Andrade-Romero, J. Alexis ; Herrera, Victoria ; Romero, J. Franklin A
Author_Institution
Programa de Pos-Grad. em Energia, Univ. Fed. do ABC, São Paulo, Brazil
fYear
2012
fDate
25-28 Oct. 2012
Firstpage
627
Lastpage
631
Abstract
It is proposed a novel fault detection technique applied on indirect matrix converter (IMC) in order to detect open circuit faults in bidirectional switches. An IMC under input power factor control in generation systems based on Microturbine (MT) is considered in this study. The IMC under open-circuited switch failures provides continuous operation, since the performance detriment is not drastic although power quality considerably decrease. This work will focus this particular case where faults are not quite evident. The proposed detection technique is based on the continuous wavelet transform and the global wavelet spectrum function applied to the IMC input current. Simulation results are presented in order to verify the proposed diagnostic tool.
Keywords
matrix convertors; power factor; power generation control; power generation faults; power supply quality; turbines; wavelet transforms; IMC; continuous wavelet transform; global wavelet spectrum function; indirect matrix converter; input power factor control; microturbine generation systems; open-circuit fault detection analysis; open-circuited switch failures; power quality; Argon; Continuous wavelet transforms; Load flow; Monitoring; Sensors; Continuous Wavelet Transforms; Distributed Power Generation; Electrical fault detection; Matrix Converters;
fLanguage
English
Publisher
ieee
Conference_Titel
IECON 2012 - 38th Annual Conference on IEEE Industrial Electronics Society
Conference_Location
Montreal, QC
ISSN
1553-572X
Print_ISBN
978-1-4673-2419-9
Electronic_ISBN
1553-572X
Type
conf
DOI
10.1109/IECON.2012.6388755
Filename
6388755
Link To Document