DocumentCode :
2631988
Title :
Open-Circuit fault detection analysis for indirect matrix converter in Microturbine generation systems
Author :
Andrade-Romero, J. Alexis ; Herrera, Victoria ; Romero, J. Franklin A
Author_Institution :
Programa de Pos-Grad. em Energia, Univ. Fed. do ABC, São Paulo, Brazil
fYear :
2012
fDate :
25-28 Oct. 2012
Firstpage :
627
Lastpage :
631
Abstract :
It is proposed a novel fault detection technique applied on indirect matrix converter (IMC) in order to detect open circuit faults in bidirectional switches. An IMC under input power factor control in generation systems based on Microturbine (MT) is considered in this study. The IMC under open-circuited switch failures provides continuous operation, since the performance detriment is not drastic although power quality considerably decrease. This work will focus this particular case where faults are not quite evident. The proposed detection technique is based on the continuous wavelet transform and the global wavelet spectrum function applied to the IMC input current. Simulation results are presented in order to verify the proposed diagnostic tool.
Keywords :
matrix convertors; power factor; power generation control; power generation faults; power supply quality; turbines; wavelet transforms; IMC; continuous wavelet transform; global wavelet spectrum function; indirect matrix converter; input power factor control; microturbine generation systems; open-circuit fault detection analysis; open-circuited switch failures; power quality; Argon; Continuous wavelet transforms; Load flow; Monitoring; Sensors; Continuous Wavelet Transforms; Distributed Power Generation; Electrical fault detection; Matrix Converters;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
IECON 2012 - 38th Annual Conference on IEEE Industrial Electronics Society
Conference_Location :
Montreal, QC
ISSN :
1553-572X
Print_ISBN :
978-1-4673-2419-9
Electronic_ISBN :
1553-572X
Type :
conf
DOI :
10.1109/IECON.2012.6388755