Abstract :
A simple pre-stress estimate method of Langevin transducers is studied. The measurement setup consists of a capacitor, an impedance converter and a voltmeter. Based on the piezoelectric equation and the basic circuit theory, the mathematical expression between the pre-stress and the voltage across the capacitor is derived. The pre-stress level can then be calculated out of the measurement of the capacitor voltage. In order to evaluate the precision of this method, a force washer is used to measure the pre-stress of the Langevin transducer. The result shows the pre-stress level obtained from this method is 30-40% higher than the pre-stress level measured by the force washer. This method is simple and can be used to estimate the pre-stress of various Langevin transducers. The precision of this method can be raised if d33 is identified under different pre-stress levels.
Keywords :
capacitors; impedance convertors; piezoelectric transducers; stress analysis; Langevin transducers; basic circuit theory; capacitor; impedance converter; piezoelectric equation; pre-stress estimating method; voltmeter; Capacitors; Educational institutions; Equations; Force measurement; Impedance measurement; Manufacturing; Mechatronics; Piezoelectric transducers; Voltage; Voltmeters; Langevin transducer; capacitor; piezoelectric element; pre-stress;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Piezoelectricity, Acoustic Waves, and Device Applications, 2008. SPAWDA 2008. Symposium on
Conference_Location :
Nanjing
Print_ISBN :
978-1-4244-2891-5
Type :
conf
DOI :
10.1109/SPAWDA.2008.4775801
Filename :
4775801
Link To Document :
بازگشت