Abstract
Renovation work has been carried out to separate the 3 kN/500 N dead-weight type force standard machine (DWM) at the National Metrology Institute of Japan. Two loading frames and a common structural frame were newly manufactured. No significant changes were observed in the calibration results of several force transducers before and after the renovation; in some cases, there has even been improvement in terms of repeatability and reproducibility of the calibration results. The renovation has made it possible to operate the two weight stacks simultaneously and to improve the working efficiency of calibration, while maintaining the reliability of the DWMs as the National Force Standards.
Keywords
calibration; force measurement; measurement standards; quality control; reliability; calibration; force standard machine; force transducer; loading frame; quality control; reliability; reproducibility; structural frame; weight stacks; working efficiency; Calibration; Clamps; Fasteners; Fluctuations; Force measurement; Maintenance; Manufacturing; Metrology; Quality control; Steel; DWM; Working efficiency; force standard; simultaneous operation;
fLanguage
English
Publisher
ieee
Conference_Titel
SICE, 2007 Annual Conference
Conference_Location
Takamatsu
Print_ISBN
978-4-907764-27-2
Electronic_ISBN
978-4-907764-27-2
Type
conf
DOI
10.1109/SICE.2007.4420947
Filename
4420947
Link To Document