DocumentCode :
2635676
Title :
Once in ten thousand years [railway signalling systems]
Author :
Bailey, D.F.
fYear :
1995
fDate :
27-30 Mar 1995
Firstpage :
158
Lastpage :
160
Abstract :
The author discusses fail safe railway signalling systems and their failure. The investigation of `wrong side´ signalling failures is discussed. Examples of reliability and wrong side failure investigations are given. The failures covered include silver and copper ions migration in contacts, solid state interlocking (SSI) problems, and interference from traction systems and track circuits
fLanguage :
English
Publisher :
iet
Conference_Titel :
Electric Railways in a United Europe, 1995., International Conference on
Conference_Location :
Amsterdam
Print_ISBN :
0-85296-631-8
Type :
conf
DOI :
10.1049/cp:19950198
Filename :
396029
Link To Document :
بازگشت