• DocumentCode
    2635856
  • Title

    A high integrity monitor for signalling interference prevention at 50 Hz

  • Author

    Crookes, R.W ; Oates, C.D.M. ; Brooks, D.M. ; Cowen, M.

  • Author_Institution
    GEC Alsthom Eng. Res. Centre, Stafford, UK
  • fYear
    1995
  • fDate
    27-30 Mar 1995
  • Firstpage
    143
  • Lastpage
    147
  • Abstract
    The design of a high integrity monitor for the prevention of signalling interference is described. It belongs to the family known as Interference Current Monitor Units, or ICMUs, and has to be extremely reliable since a fault would otherwise compromise railway safety; a calculated value of Mean Time Between Wrong Side Failure (MTBWSF) of five thousand million hours was specified and achieved. High levels of out of band currents had to be rejected, in particular up to 2 kA DC The basic design was kept as simple as possible with only one frequency band being detected. A hardware only solution, i.e. no software, was adopted and triplication of the circuit was used to achieve the MTBWSF specification
  • Keywords
    automatic test equipment; computerised monitoring; electric current measurement; interference suppression; railways; reliability; safety; signalling; 2 kA; 50 Hz; Interference Current Monitor Units; Mean Time Between Wrong Side Failure; high integrity monitor; out of band currents; railway safety; signalling interference prevention;
  • fLanguage
    English
  • Publisher
    iet
  • Conference_Titel
    Electric Railways in a United Europe, 1995., International Conference on
  • Conference_Location
    Amsterdam
  • Print_ISBN
    0-85296-631-8
  • Type

    conf

  • DOI
    10.1049/cp:19950195
  • Filename
    396040