DocumentCode :
2636145
Title :
A High Precision Swept Rf Reflectometer System in Coaxial Line
Author :
Lacy, Peter ; Oldfield, William
fYear :
1973
fDate :
4-6 June 1973
Firstpage :
151
Lastpage :
151
Abstract :
A system is presented which provides a decade improvement in voltage reflection coefficient measurement accuracy over the range of 0 to 50 dB return loss. The technique separates the unknown from the error signals. Two methods using a combination of old and new techniques are presented Error Averaging and Magnified Swept Sensor. The basic ingredients are precision airline and directional bridge. A mathematical review of the old and the new reflectometer methods will be included.
Keywords :
Bridge circuits; Coaxial components; Loss measurement; Reflection; Voltage measurement;