• DocumentCode
    2637278
  • Title

    Effect of operational amplifier parameters on the performance of feedback structures with thermoresistive sensors

  • Author

    Freire, Raimundo C S ; Deep, Gurdip S. ; Oliveira, Amauri

  • Author_Institution
    UFPB-CCT-DEE, Campina Grande, Brazil
  • Volume
    2
  • fYear
    1997
  • fDate
    19-21 May 1997
  • Firstpage
    898
  • Abstract
    Feedback circuits with thermoresistive sensors have been widely used in the measurement of thermal radiation and fluid flow. In general, the operation of these circuits is explained assuming an ideal operational amplifier used in the feedback configuration. The effect of various limiting parameters of the operational amplifier on the static and dynamic performance has been analyzed. The error introduced when used as a measuring device, due to input offset voltage is estimated
  • Keywords
    anemometers; bridge circuits; circuit stability; dynamic response; electric sensing devices; equivalent circuits; feedback amplifiers; flowmeters; measurement errors; operational amplifiers; temperature sensors; bridge configuration; common mode; differential gain; dynamic performance; dynamic response; error estimation; feedback circuits; feedback structures; ideal operational amplifier; input offset voltage; limiting parameters; operational amplifier parameters effect; static performance; thermal flow sensor; thermoresistive sensors; Feedback circuits; Fluid flow; Fluid flow measurement; Operational amplifiers; Power measurement; Sensor phenomena and characterization; Temperature sensors; Thermal sensors; Thermoresistivity; Voltage;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Instrumentation and Measurement Technology Conference, 1997. IMTC/97. Proceedings. Sensing, Processing, Networking., IEEE
  • Conference_Location
    Ottawa, Ont.
  • ISSN
    1091-5281
  • Print_ISBN
    0-7803-3747-6
  • Type

    conf

  • DOI
    10.1109/IMTC.1997.610254
  • Filename
    610254