• DocumentCode
    2637575
  • Title

    New method for RF field amplitude and phase calibration in flash accelerator

  • Author

    Pawlik, P. ; Grecki, M. ; Simrock, S.

  • Author_Institution
    Tech. Univ. of Lodz
  • fYear
    2006
  • fDate
    22-24 June 2006
  • Firstpage
    85
  • Lastpage
    88
  • Abstract
    The paper presents new method for amplitude and phase calibration of the RF field in FLASH accelerator. The concept is based for detection and measurement of transients induced by single bunch. These transients are very small and it is not possible to detect them without special hardware. The paper presents the measurement system developed for a single bunch induced transient detection. The results of measurement obtained with this system are presented proving its correct operation
  • Keywords
    accelerator RF systems; calibration; free electron lasers; FLASH accelerator; RF field amplitude calibration; comb filter; phase calibration; transient detection; transient measurement; Acceleration; Calibration; Delay; Electromagnetic fields; Electron beams; Hardware; Klystrons; Particle beams; Probes; Radio frequency;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Mixed Design of Integrated Circuits and System, 2006. MIXDES 2006. Proceedings of the International Conference
  • Conference_Location
    Gdynia
  • Print_ISBN
    83-922632-2-7
  • Type

    conf

  • DOI
    10.1109/MIXDES.2006.1706543
  • Filename
    1706543