DocumentCode
2639143
Title
Guaranteed cost control of the water level of steam generator based on T-S model
Author
Xiujuan, Zhuo ; Junling, Wang ; Zhangjun, Feng
Author_Institution
Coll. of Nucl. Sci. & Technol., Harbin Eng. Univ., Harbin
fYear
2008
fDate
10-12 Dec. 2008
Firstpage
1
Lastpage
5
Abstract
In the operation of nuclear steam generator, the reverse thermal-dynamic effects make steam generator water level process dynamics characteristic difficult to control. In order to improve the control effect, a guaranteed cost controller method based on T-S model for the water level control of a nuclear steam generator is proposed and investigated in this paper. The proposed controller guarantees both stability and a prescribed performance in the entire operating region in terms of linear matrix inequalities. The computer simulation shows that guaranteed cost controller can efficiently control the steam generator water level and achieve anticipative effects. It also demonstrates the effectiveness of the proposed controller in full operating range.
Keywords
boilers; cost optimal control; fuzzy control; linear matrix inequalities; nuclear power stations; stability; T-S model; guaranteed cost control; linear matrix inequalities; nuclear steam generator; reverse thermal-dynamic effects; stability; water level control; Character generation; Computer simulation; Costs; Level control; Linear matrix inequalities; Nuclear power generation; Stability; Water;
fLanguage
English
Publisher
ieee
Conference_Titel
Systems and Control in Aerospace and Astronautics, 2008. ISSCAA 2008. 2nd International Symposium on
Conference_Location
Shenzhen
Print_ISBN
978-1-4244-3908-9
Electronic_ISBN
978-1-4244-2386-6
Type
conf
DOI
10.1109/ISSCAA.2008.4776357
Filename
4776357
Link To Document