DocumentCode :
2639994
Title :
Hysteresis, PI and Ramptime Current Control Techniques for APF: An experimental comparison
Author :
Daniyal, Hamdan ; Lam, Eric ; Borle, Lawrence J. ; Iu, Herbert H C
Author_Institution :
Sch. of EECE, Univ. of Western Australia, Crawley, WA, Australia
fYear :
2011
fDate :
21-23 June 2011
Firstpage :
2151
Lastpage :
2156
Abstract :
This paper presents an experimental comparison of three current control techniques, namely Hysteresis, PI and Ramptime Current Control Techniques. The testing platform is a 300 W shunt active power filter with diode rectifier load. Results are analysed both in the time domain and the frequency domain. The pros and cons of each of the above mentioned current control techniques are discussed. It is found that Ramptime Current Control is capable of incorporating the advantages of the two other control techniques with negligible shortcomings.
Keywords :
PI control; active filters; diodes; electric current control; power filters; rectifiers; APF; PI control; diode rectifier load; hysteresis control; power 400 W; ramptime current control techniques; shunt active power filter; Active filters; Current control; Harmonic analysis; Hysteresis; Power harmonic filters; Switches; Switching frequency; APF; active power filter; current control; harmonics;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Industrial Electronics and Applications (ICIEA), 2011 6th IEEE Conference on
Conference_Location :
Beijing
ISSN :
pending
Print_ISBN :
978-1-4244-8754-7
Electronic_ISBN :
pending
Type :
conf
DOI :
10.1109/ICIEA.2011.5975947
Filename :
5975947
Link To Document :