DocumentCode
264191
Title
Induced voltage unbalance on a permanent magnet motor with armature failures
Author
Alvarez, J.A. ; Peralta, E. ; Espino, F.P.
fYear
2014
fDate
5-7 Nov. 2014
Firstpage
1
Lastpage
6
Abstract
This paper addresses the calculation of the induced voltage in the stator winding of a permanent magnet synchronous motor under armature fault conditions. The generalized harmonic analysis is used to model the motor winding and the magnetic field in the air gap produced by the permanent magnet. Simulation results of unbalanced induced voltage are illustrated and analyzed in detail.
Keywords
permanent magnet motors; stators; synchronous motors; armature fault; harmonic analysis; magnetic field; motor winding; permanent magnet synchronous motor; stator winding; Mathematical model; Nuclear magnetic resonance; Permanent magnet motors; Rotors; Silicon compounds; Stator windings; Synchronous motors; Análisis armónico generalizado; fallas en devanados de armadura; motor de imán permanente;
fLanguage
English
Publisher
ieee
Conference_Titel
Power, Electronics and Computing (ROPEC), 2014 IEEE International Autumn Meeting on
Conference_Location
Ixtapa
Type
conf
DOI
10.1109/ROPEC.2014.7036313
Filename
7036313
Link To Document