• DocumentCode
    264191
  • Title

    Induced voltage unbalance on a permanent magnet motor with armature failures

  • Author

    Alvarez, J.A. ; Peralta, E. ; Espino, F.P.

  • fYear
    2014
  • fDate
    5-7 Nov. 2014
  • Firstpage
    1
  • Lastpage
    6
  • Abstract
    This paper addresses the calculation of the induced voltage in the stator winding of a permanent magnet synchronous motor under armature fault conditions. The generalized harmonic analysis is used to model the motor winding and the magnetic field in the air gap produced by the permanent magnet. Simulation results of unbalanced induced voltage are illustrated and analyzed in detail.
  • Keywords
    permanent magnet motors; stators; synchronous motors; armature fault; harmonic analysis; magnetic field; motor winding; permanent magnet synchronous motor; stator winding; Mathematical model; Nuclear magnetic resonance; Permanent magnet motors; Rotors; Silicon compounds; Stator windings; Synchronous motors; Análisis armónico generalizado; fallas en devanados de armadura; motor de imán permanente;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Power, Electronics and Computing (ROPEC), 2014 IEEE International Autumn Meeting on
  • Conference_Location
    Ixtapa
  • Type

    conf

  • DOI
    10.1109/ROPEC.2014.7036313
  • Filename
    7036313