Title :
Third Generation Automatic Microwave Measurements
Abstract :
A microwave measurement system is described that is used with our third generation test equipment to achieve automatic microwave measurements of signals in the frequency range of 10 MHZ to 18 GHz. This system down-converts input signals in the range of 2 GHz to 18 GHz so that through the utilization of sampling techniques and computer software automatic microwave measurements of frequency, power, spectrum analyses, and modulation are achieved. Signals from 10 MHz to 2 GHz are first up-converted and applied to the microwave circuits for down conversion.
Keywords :
Frequency measurement; Microwave devices; Microwave generation; Microwave measurements; Microwave theory and techniques; Power measurement; Sampling methods; Signal generators; Software; Test equipment;
Conference_Titel :
Microwave Symposium, 1976 IEEE-MTT-S International
Conference_Location :
Cherry Hill, NJ, USA
DOI :
10.1109/MWSYM.1976.1123699