Title :
Fault diagnosis method using a signed digraph for multiple origins of failures - evaluation of the diagnosis accuracy -
Author :
Tateno, Shigeyuki ; Matsuyama, Hisayoshi ; Tsuge, Yoshifumi
Author_Institution :
Waseda Univ., Kitakyushu
Abstract :
A fault diagnosis algorithm using a signed digraph as a model of a system is useful to real-time diagnosis of failures that occur in a chemical plant. It has been improved so much that it can find multiple origins of failures that occur in the plant at the same time. It is imperative that the diagnosis system be evaluated in the design phase of the system in advance for its practical use. In this paper, an accuracy of diagnostic results using the algorithm for multiple origins has been examined by its application to data obtained by the simulation of tank pipeline systems. The accuracy of diagnosis has been evaluated properly by the size of the greatest set of candidates
Keywords :
chemical industry; fault diagnosis; graph theory; pipelines; chemical plant; fault diagnosis; realtime failure diagnosis; signed digraph; tank pipeline systems; Chemical processes; Fault diagnosis; Helium; Large-scale systems; Pipelines; Real time systems; Steady-state;
Conference_Titel :
Computer Aided Control System Design, 2006 IEEE International Conference on Control Applications, 2006 IEEE International Symposium on Intelligent Control, 2006 IEEE
Conference_Location :
Munich
Print_ISBN :
0-7803-9797-5
Electronic_ISBN :
0-7803-9797-5
DOI :
10.1109/CACSD-CCA-ISIC.2006.4777162