Abstract :
Broken rotor bar/ end-ring is a common fault in squirrel cage induction motors and has been thoroughly investigated in the case of AC grid supply. In this paper, this type of fault is studied in case of inverter driven motor. Induction motor is driven using scalar Volts/ Hz control method. Motor stator current and inverter input current spectra are studied for frequency components due to fault. Inverter input current spectrum gives the ability of fault detection and severity classification, even under low load and low motor severity fault condition in steady-state more easily than using motor stator current data, as it has the capability to produce advantage in variable frequency operation.
Keywords :
induction motors; invertors; rotors; squirrel cage motors; inverter drive systems; inverter input current analysis; rotor fault detection; squirrel cage induction motors; variable frequency operation; Computers; Fault diagnosis; Induction motors; Inverters; Rotors; Simulation; Stators; Fault diagnosis; induction motors; inverter; spectral analysis;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electrical Machines (ICEM), 2010 XIX International Conference on
Conference_Location :
Rome
Print_ISBN :
978-1-4244-4174-7
Electronic_ISBN :
978-1-4244-4175-4
Type :
conf
DOI :
10.1109/ICELMACH.2010.5608038
Filename :
5608038
Link To Document :
بازگشت