Title :
Suppression of nickel release in nickeltitanium alloys by plasma immersion ion implantation surface treatment: towards a new generation of "smart" orthopaedic implants
Author :
Yeung, K.W.K. ; Chan, Y.L. ; Chan, S.C.W. ; Liu, X.Y. ; Chung, C.Y. ; Chu, P.K. ; Lu, W.W. ; Luk, K.D.K. ; Chan, D. ; Cheung, K.M.C.
Author_Institution :
Dept. of Orthopaedics & Traumatology, Hong Kong Univ.
Abstract :
Summary form only given. Nickel-titanium shape memory alloys (NiTi) are potentially very useful in spinal deformity correction due to their super elastic properties and their ability to change shape with temperature. However, release of toxic nickel particulate debris remains a major concern. We have developed a novel method of altering the surface of the material to reduce nickel release by using plasma immersion ion implantation (PIII). This study compares the corrosion resistance and mechanical properties of PIII treated samples with untreated NiTi. NiTi discs containing 50.8% Ni were implanted with nitrogen using PIII technique. Their elemental depth profile, surface chemical composition, surface hardness and corrosion resistance were compared with untreated NiTi. The amount of Ni released into simulated body fluids after the accelerated corrosion tests were determined. The biocompatibility was assessed by culturing mouse osteoblasts expressing an enhanced green fluorescent protein on the surface of these materials. After PIII treatment, a layer of titanium nitride formed on the surface. Compared to untreated NiTi, the corrosion resistance is better by five times, and the surface hardness and elastic modulus are better by a factor of 2. The concentration of Ni in the simulated body fluid for the untreated sample was 30 ppm compared to undetectable levels in the PIII treated sample. There was no difference in the ability of cells to grow on either surface. PIII results in enhanced corrosion and wear resistance, and negligible Ni release. This technique will allow NiTi alloys to be safely implanted in the human body. A new generation of "smart" orthopaedic implants will likely result
Keywords :
biomedical materials; corrosion resistance; elastic moduli; elasticity; hardness; intelligent materials; nickel alloys; orthopaedics; plasma immersion ion implantation; prosthetics; proteins; surface composition; surface treatment; titanium alloys; wear resistance; NiTi; PIII; biocompatibility; corrosion resistance; elastic modulus; elemental depth profile; green fluorescent protein; mechanical properties; mouse osteoblasts; nickel-titanium shape memory alloys; plasma immersion ion implantation; simulated body fluids; smart orthopaedic implants; spinal deformity correction; surface chemical composition; surface hardness; surface treatment; toxic nickel particulate debris; wear resistance; Corrosion; Immune system; Implants; Nickel alloys; Orthopedic surgery; Plasma immersion ion implantation; Plasma temperature; Shape memory alloys; Surface resistance; Surface treatment;
Conference_Titel :
Plasma Science, 2006. ICOPS 2006. IEEE Conference Record - Abstracts. The 33rd IEEE International Conference on
Conference_Location :
Traverse City, MI
Print_ISBN :
1-4244-0125-9
DOI :
10.1109/PLASMA.2006.1707307