Abstract :
A pulse duoplasmatron with a cold cathode used at preinjectors of the ITEP proton linacs has been tested for generation of a dc proton beam. The operation of the duoplasmatron was studied experimentally with low currents of the discharge. The test bench experiments allowed to modify construction of a pulsed ion source for stable dc operation with a high lifetime. The ion source generated a dc beam of protons with a current ≈12 mA at 30 kV
Keywords :
cathodes; duoplasmatrons; 30 kV; ITEP; cold cathode; cw operation; dc operation; duoplasmatron; proton linac; pulsed ion source; Cathodes; DC generators; Fault location; Ion sources; Life testing; Linear accelerators; Particle beams; Protons; Pulse generation; Structural beams;