• DocumentCode
    2654197
  • Title

    Reasons for using IEEE standard 841-1994 motors for the forest products industry

  • Author

    Holmquist, J.R.

  • Author_Institution
    Weyerhaeuser Co., Tacoma, WA, USA
  • fYear
    1998
  • fDate
    21-26 June 1998
  • Firstpage
    87
  • Lastpage
    96
  • Abstract
    This paper is a review of efforts taken toward understanding the Total Cost of Ownership (TCO) for AC electric motors and the benefits to be derived by using IEEE Standard 841-1994 motors. The paper describes a corporate policy to reduce TCO of AC electric motors and corporate´s program for product evaluation. The paper also considers repair/replace and retrofit options. The conclusions reached could apply to all forest products industry companies as well as to most other continuous process industrial companies.
  • Keywords
    AC motors; IEEE standards; costing; economics; energy conservation; forestry; power consumption; wood processing; AC electric motors; IEEE standard 841-1994 motors; continuous process industries; corporate policy; forest products industry; motor economics; product evaluation; repair; replace; retrofit; total cost of ownership; AC motors; Costs; Electric motors; Energy efficiency; Life members; Manufacturing; Milling machines; Testing; Warranties; Writing;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Pulp and Paper Industry Technical Conference, 1998. Conference Record of 1998 Annual
  • Conference_Location
    Portland, ME, USA
  • ISSN
    0190-2172
  • Print_ISBN
    0-7803-4785-4
  • Type

    conf

  • DOI
    10.1109/PAPCON.1998.685508
  • Filename
    685508