• DocumentCode
    2655692
  • Title

    Note on the SC linear collider TESLA cavity design

  • Author

    Sekutowicz, J. ; Proch, D. ; Tang, C.

  • Author_Institution
    DESY, Hamburg, Germany
  • Volume
    3
  • fYear
    1997
  • fDate
    12-16 May 1997
  • Firstpage
    3081
  • Abstract
    The experience we have gained over the last few years from experiments with superconducting cavities for the TESLA test facility, justifies a revision of the design proposed almost five years ago. The proposed new design presented takes advantage of the high quality factor Q0>1010 and low electron emission at the specified accelerating field of 25 MV/m, as demonstrated by some tested cavities. The main aim of the design is to simplify production and preparation of superconducting cavities and thus to reduce the cost of the linear collider. The new cavity shape has an enlarged iris diameter with the following advantages: significantly lower loss factors, a simplified and less expensive scheme for the HOM damping and the suitability of hydroforming and higher stability of the field profile
  • Keywords
    Q-factor; accelerator RF systems; accelerator cavities; electron accelerators; linear colliders; superconducting cavity resonators; 1.3 GHz; HOM damping; Q0; TESLA; cavity shape; electron emission; field profile; hydroforming; iris; linear collider; loss factor; quality factor; superconducting cavities; Costs; Damping; Electron emission; Iris; Life estimation; Production; Q factor; Shape; Test facilities; Testing;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Particle Accelerator Conference, 1997. Proceedings of the 1997
  • Conference_Location
    Vancouver, BC
  • Print_ISBN
    0-7803-4376-X
  • Type

    conf

  • DOI
    10.1109/PAC.1997.753115
  • Filename
    753115